Inverter Battery Runtime CalculatorHours of power from your battery at any load
Enter the load your inverter will power, your battery’s amp-hour rating and voltage, and its chemistry. The calculator allows for inverter losses, safe depth of discharge and the way lead-acid batteries deliver less at high current, then shows realistic runtime and a table for other loads.
Battery and load
How to use the Inverter Battery Runtime Calculator
- Add up the load: the watts of every device that will run at the same time. The label or charger brick shows each device’s watts.
- Enter your battery’s capacity in amp-hours (Ah) and its voltage. For two 12 V batteries in parallel, add the Ah; in series, double the voltage and keep the Ah.
- Choose the battery type. It sets how much of the capacity you can safely use.
- Enter the inverter efficiency from its specifications, or leave 90%.
Usable capacity by battery type
| Battery type | Usable capacity | Notes |
|---|---|---|
| Car starter battery | About 20 to 30% | Not designed for deep discharge |
| Flooded deep-cycle | About 50% | Cheapest per Ah; needs topping up and venting |
| AGM or gel | About 50% | Sealed and maintenance-free |
| Lithium (LiFePO4) | 80 to 100% | Light, long life, holds voltage steady |
Discharging lead-acid batteries below about 50% shortens their life sharply. Lithium iron phosphate batteries handle deep cycles well and often last 3,000 or more cycles.
The Peukert effect
Lead-acid batteries are rated at the 20-hour rate: a 100Ah battery delivers 5 A for 20 hours. Draw 30 A and it delivers noticeably less than 100Ah in total. This is the Peukert effect, and it is why big inverter loads drain lead-acid batteries faster than simple math suggests. Lithium batteries are affected much less, so their real runtime is closer to the rating.
Don’t forget the inverter itself
- Conversion loss: inverters waste 8% to 15% of the power as heat, more at very light loads.
- Idle draw: a large inverter can use 10 to 30 W with nothing plugged in. Turn it off when not in use.
- Surge loads: motors, compressors and pumps need two to three times their running watts for a moment at start-up.
Tips for longer runtime
- Run 12 V devices directly where possible, such as 12 V fridges and USB chargers, to skip inverter losses.
- Use a higher-voltage system (24 V or 48 V) for large loads, which halves or quarters the current.
- Size cables and fuses correctly. At 12 V, a 1,000 W inverter draws about 90 A or more.
- Recharge promptly. Leaving lead-acid batteries partly discharged causes sulfation.
The formulas
Runtime = 20 h × (Ah ÷ (Current × 20 h))k × Usable fraction
Peukert exponent k: flooded 1.25 · AGM 1.15 · lithium 1.05
Battery runtime facts
Frequently asked questions
How long will a 100Ah battery run a 1000W inverter?
How long will a 100Ah battery run a 300W load?
How do I calculate battery runtime?
Is lithium worth it for an inverter?
Can I run an inverter from my car battery?
Should I use a 12V or 24V system?
Related tools and guides
Reviews of related gear
Choosing an inverter?
Read our car accessory reviews and buying guides.
Estimates for a healthy, fully charged battery at room temperature. Cold, battery age and inverter idle draw reduce real runtime.