Inverter Battery Runtime CalculatorHours of power from your battery at any load

Enter the load your inverter will power, your battery’s amp-hour rating and voltage, and its chemistry. The calculator allows for inverter losses, safe depth of discharge and the way lead-acid batteries deliver less at high current, then shows realistic runtime and a table for other loads.

Free, no sign-upLead-acid, AGM & lithiumPeukert adjustedBy ReviewsWhiz Editorial Team

Battery and load

W
Add up the watts of everything running at once.
Ah
For several batteries in parallel, add their Ah.
%
85 to 92% is typical for pure sine wave inverters.

How to use the Inverter Battery Runtime Calculator

  1. Add up the load: the watts of every device that will run at the same time. The label or charger brick shows each device’s watts.
  2. Enter your battery’s capacity in amp-hours (Ah) and its voltage. For two 12 V batteries in parallel, add the Ah; in series, double the voltage and keep the Ah.
  3. Choose the battery type. It sets how much of the capacity you can safely use.
  4. Enter the inverter efficiency from its specifications, or leave 90%.
Quick answer: divide the battery’s usable watt-hours by the load, allowing for inverter loss. A 100Ah 12 V lithium battery has about 1,080 Wh usable, so it runs a 300 W load for about 3 hours. The same size AGM battery, where only half is usable and high current reduces capacity, runs it for about 1.4 hours.

Usable capacity by battery type

Battery typeUsable capacityNotes
Car starter batteryAbout 20 to 30%Not designed for deep discharge
Flooded deep-cycleAbout 50%Cheapest per Ah; needs topping up and venting
AGM or gelAbout 50%Sealed and maintenance-free
Lithium (LiFePO4)80 to 100%Light, long life, holds voltage steady

Discharging lead-acid batteries below about 50% shortens their life sharply. Lithium iron phosphate batteries handle deep cycles well and often last 3,000 or more cycles.

The Peukert effect

Lead-acid batteries are rated at the 20-hour rate: a 100Ah battery delivers 5 A for 20 hours. Draw 30 A and it delivers noticeably less than 100Ah in total. This is the Peukert effect, and it is why big inverter loads drain lead-acid batteries faster than simple math suggests. Lithium batteries are affected much less, so their real runtime is closer to the rating.

Don’t forget the inverter itself

  • Conversion loss: inverters waste 8% to 15% of the power as heat, more at very light loads.
  • Idle draw: a large inverter can use 10 to 30 W with nothing plugged in. Turn it off when not in use.
  • Surge loads: motors, compressors and pumps need two to three times their running watts for a moment at start-up.

Tips for longer runtime

  • Run 12 V devices directly where possible, such as 12 V fridges and USB chargers, to skip inverter losses.
  • Use a higher-voltage system (24 V or 48 V) for large loads, which halves or quarters the current.
  • Size cables and fuses correctly. At 12 V, a 1,000 W inverter draws about 90 A or more.
  • Recharge promptly. Leaving lead-acid batteries partly discharged causes sulfation.

The formulas

Battery current = Load W ÷ (Battery V × Inverter efficiency)
Runtime = 20 h × (Ah ÷ (Current × 20 h))k × Usable fraction
Peukert exponent k: flooded 1.25 · AGM 1.15 · lithium 1.05

Battery runtime facts

50%
Safe usable capacity of lead-acid batteries.
90%
Typical usable capacity of LiFePO4.
85 to 92%
Typical inverter efficiency.
20-hour rate
How lead-acid Ah ratings are measured.
About 90 A
Draw of a 1,000 W inverter at 12 V.
Idle draw
Large inverters use power even with no load.

Frequently asked questions

How long will a 100Ah battery run a 1000W inverter?
A 100Ah 12 V lithium battery runs a full 1,000 W load for about 50 minutes. An AGM battery of the same size manages only about 20 minutes before reaching 50% charge.
How long will a 100Ah battery run a 300W load?
About 3 hours on lithium and about 1.4 hours on AGM, allowing for inverter losses and safe depth of discharge.
How do I calculate battery runtime?
Multiply the Ah by the voltage and the usable fraction to get watt-hours, then divide by the load in watts plus inverter losses.
Is lithium worth it for an inverter?
For frequent or heavy use, usually yes. You can use almost all of its capacity, it is lighter, and it lasts many more cycles than lead-acid.
Can I run an inverter from my car battery?
Only for small loads and short periods, ideally with the engine running. Starter batteries are not made for deep discharge.
Should I use a 12V or 24V system?
For loads over about 1,500 W, 24 V or 48 V systems are better. They halve the current, allowing thinner cables and smaller fuses.

Related tools and guides

Reviews of related gear

Choosing an inverter?

Read our car accessory reviews and buying guides.

Read the reviews →

Estimates for a healthy, fully charged battery at room temperature. Cold, battery age and inverter idle draw reduce real runtime.